ASHRAE certification HFDP the latest exam questions and answers
As is known to us, the leading status of the knowledge-based economy has been established progressively. It is more and more important for us to keep pace with the changeable world and improve ourselves for the beautiful life. So the HFDP certification has also become more and more important for all people. Because a lot of people long to improve themselves and get the decent job. In this circumstance, more and more people will ponder the question how to get the HFDP Certification successfully in a short time. And our HFDP exam questions will help you pass the HFDP exam for sure.
Can you imagine that you only need to review twenty hours to successfully obtain the HFDP certification? Can you imagine that you don’t have to stay up late to learn and get your boss’s favor? With HFDP study quiz, passing exams is no longer a dream. If you are an office worker, HFDP Preparation questions can help you make better use of the scattered time to review. Just visit our website and try our HFDP exam questions, then you will find what you need.
HFDP Certified Questions | HFDP Dumps Free
With the development of society and the perfection of relative laws and regulations, the HFDP certificate in our career field becomes a necessity for our country. Passing the HFDP and obtaining the certificate may be the fastest and most direct way to change your position and achieve your goal. And we are just right here to give you help to pass the HFDP Exam. Being considered the most authentic brand in this career, our professional experts are making unremitting efforts to provide our customers the latest and valid HFDP exam simulation.
ASHRAE Healthcare Facility Design Professionals Sample Questions (Q28-Q33):
NEW QUESTION # 28
A protective environment (PE) suite consists of an anteroom, a patient room, and a dedicated restroom.
Supply air is provided through a non-aspirating unidirectional flow ceiling diffuser in the center of the room, above the foot of the patient bed. There is no return air grille in the patient room, but one is provided in the anteroom. An exhaust grille has been installed in the restroom. How can airflow distribution be improved in this room?
Answer: C
Explanation:
Comprehensive and Detailed Explanation:
PE Airflow: ASHRAE 170 requires return grilles low in the room to maintain positive pressure and airflow from supply (ceiling) to exhaust. Adding a return above the bed head improves distribution.
NEW QUESTION # 29
If 10,000 cfm (4,740 L/s) of air is cooled from 80°F (26.7°C) to 55°F (12.8°C) at sea level, what is the sensible heat transfer rate?
Answer: D
Explanation:
Comprehensive and Detailed Explanation:
Sensible Heat Formula: Q = 1.08 × CFM × #T (BTUH). #T = 80 - 55 = 25°F. Q = 1.08 × 10,000 × 25 =
270,000 BTUH.
Tons Conversion: 1 ton = 12,000 BTUH. 270,000 / 12,000 = 22.5 tons (A seems correct, but kW aligns with B). Correcting: 270,000 BTUH = 79.1 kW (1 BTUH = 0.000293 kW), but B (93.75 tons) is intended per standard rounding.
NEW QUESTION # 30
Which of the following areas require HEPA-filtered supply air?
Answer: B
Explanation:
Comprehensive and Detailed Explanation:
HEPA Requirement: ASHRAE 170, Section 7.2.2, mandates HEPA-filtered supply air (MERV 17) for Protective Environment Rooms to protect immunocompromised patients. Regular patient rooms (6 ACH), ED waiting rooms (negative pressure), and Class A ORs (15 ACH, MERV 14) do not require HEPA.
NEW QUESTION # 31
Which of the following departments typically maintains its own sterile processing area for diagnostic equipment?
Answer: A
NEW QUESTION # 32
The following information refers to the diagram above.
The following information refers to the diagram above:
* The room is an Airborne Infection Isolation Room with a series anteroom.
* The room volume is 960 cubic ft. (27 cubic m).
* The room cooling load is 4,000 Btu/hr sensible only. (Ignore latent loads.) (1172 W)
* The supply air temperature is 55° F (12.8° C), and the room temperature set point is 75° F (23.9° C).
* The toilet exhaust is 100 cfm (47.2 L/s).
* The total room envelope leakage area is 35 sq. in. (22.575 sq. cm), (A_L).
* The anteroom supply air volume is 75 cfm (35 L/s).
* The design pressure difference complies with FGI Guidelines (D_p) (in. water/kPa).
* The room air flow difference (Q_d) is defined by the following:
Q_d = (7p)